Optimization of a Two-Level Field-Plate Termination Structure
for Integrated-Power Applications in Ionizing Radiation Environments
  - Steven L. Kosier 
 Vicepresident of Engineering
 Technology Development
 PolarFab, Inc.
 2800, E. Old Shakopee Rd.
 Bloomington, Minnesota 55425-1350
 U.S.A.
 Email: 
                KosierS@PolarFab.Com
   
- Dragan Zupac 
 Digital DNA Laboratory
 Semiconductor Product Sector
 Motorola, Inc.
 2200, W. Broadway Road
 Mesa, Arizona 85202-1094
 U.S.A.
 Email: Dragan.Zupac@Motorola.Com
   
- 
         Ronald D. Schrimpf 
 Department of Electrical Engineering and Computer Science
 Vanderbilt University
 Box 1608, Station B
 Nashville, Tennessee 37235
 U.S.A.
 Email: 
                 Ron.Schrimpf@Vanderbilt.Edu
   
- 
         François E. Cellier 
 Institute of Computational Science
 ETH Zürich
 CH-8092 Zürich
 Switzerland
 Email: 
                FCellier@Inf.ETHZ.CH
   
- 
         Kenneth F. Galloway 
 School of Engineering
 Vanderbilt University
 VU Station B 351826
 Nashville, Tennessee 37235-1826
 U.S.A.
 Email: 
                 Kenneth.F.Galloway@Vanderbilt.Edu
   
- Mohamed N. Darwish 
 Siliconix, Inc.
 Santa Clara, California 95056
 U.S.A.
   
- C. A. Goodwin 
 AT&T Bell Laboratories
 2525, N. 12th Street
 Reading, Pennsylvania 19612-3566
 U.S.A.
   
- M. C. Dolly 
 AT&T Bell Laboratories
 Reading, Pennsylvania 19612-3566
 U.S.A.
 
Abstract
Analysis of four two-level field plate (FP) termination structures for
power-integrated circuit applications in ionizing radiation environments has
been performed through two-dimensional simulation and experiment.  Breakdown
voltage degradation as a function of the distance the upper plate overlaps the
lower plate was obtained.  Optimization of the upper plate overlap with respect
to device area and radiation hardness was accomplished. 
 
Interested in reading the
    
       full paper?
(4 pages, 234,620 bytes, pdf) 
 
   Homepage 
Last modified: January 19, 2006 -- © François Cellier